{"product_id":"125a-3-phase-distribution-board","title":"125Amp 3 Phase Distribution Board","description":"\u003cp data-end=\"1047\" data-start=\"668\"\u003eOur 125A three phase distribution board is built for larger power setups where you need a single incoming supply feeding multiple circuits safely and reliably. It suits site compounds, workshops, plant, industrial maintenance, exhibitions, outdoor installations and temporary power jobs where loads are higher, and the distribution needs to stay dependable.\u003c\/p\u003e\n\u003cp data-end=\"1346\" data-start=\"1049\"\u003eUnlike many Distribution boards that rely on lightweight moulded housings, this unit uses a hard wearing impact resistant polypropylene enclosure chosen for demanding use, with strong chemical and corrosion resistance. It is designed for real handling and transport, not just sitting in a dry cupboard.\u003c\/p\u003e\n\u003ch3 data-end=\"1393\" data-start=\"1348\"\u003eClear, confidence inspiring indication\u003c\/h3\u003e\n\u003cp data-end=\"1613\" data-start=\"1394\"\u003eEvery output has a green LED power indicator so you can see at a glance which circuits are live. A phase rotation indicator is fitted so you can quickly confirm the supply is correct before energising three phase loads.\u003c\/p\u003e\n\u003ch3 data-start=\"1361\" data-end=\"1391\"\u003eLoop out (through supply)\u003c\/h3\u003e\n\u003cp data-start=\"1392\" data-end=\"1606\"\u003eA 125A three phase loop out is fitted so you can continue the supply onwards to additional distribution boards or equipment, keeping your power layout tidy and reducing the need for splitters or separate tails.\u003c\/p\u003e\n\u003ch3 data-end=\"1221\" data-start=\"1194\"\u003eTransport and handling\u003c\/h3\u003e\n\u003cp data-end=\"1499\" data-start=\"1222\"\u003eBecause these boards get moved a lot, it’s fitted with proper carry handles for easier handling on site. The handle design also gives you solid ratchet strap points, making it simple to secure the unit during transport without worrying about the enclosure deforming or warping.\u003c\/p\u003e\n\u003ch3 data-end=\"1655\" data-start=\"1615\"\u003eIncoming protection and isolation\u003c\/h3\u003e\n\u003cp data-end=\"1861\" data-start=\"1656\"\u003eThe incoming supply is protected by a 125A four pole device providing overcurrent protection and a clear point of isolation for safe working (ideal when the unit is being moved, serviced, or reconfigured).\u003c\/p\u003e\n\u003ch3 data-end=\"1910\" data-start=\"1863\"\u003eSingle phase outputs, protected properly\u003c\/h3\u003e\n\u003cp data-end=\"2165\" data-start=\"1911\"\u003eAll single phase outputs are protected by two pole Type A RCBO protection, giving RCD protection and overcurrent protection in one device. This is the cleanest way to protect individual circuits and helps reduce nuisance tripping on real equipment loads.\u003c\/p\u003e\n\u003ch3 data-end=\"2239\" data-start=\"2167\"\u003eThree phase output protection options (depending what you select)\u003c\/h3\u003e\n\u003cp data-end=\"2423\" data-start=\"2240\"\u003eThe three phase output can be supplied with different protection options so you can match it to what you are feeding downstream, whether that is a sub board or three phase appliances.\u003c\/p\u003e\n\u003cp data-end=\"2563\" data-start=\"2425\"\u003e\u003cstrong data-end=\"2450\" data-start=\"2425\"\u003eFixed 30mA RCD option\u003c\/strong\u003e\u003cbr data-end=\"2453\" data-start=\"2450\"\u003eA good choice where you want straightforward additional protection at the output with a fixed 30mA trip level.\u003c\/p\u003e\n\u003cp data-end=\"2839\" data-start=\"2565\"\u003e\u003cstrong data-end=\"2606\" data-start=\"2565\"\u003eVariable RCD option (with key bypass)\u003c\/strong\u003e\u003cbr data-end=\"2609\" data-start=\"2606\"\u003eIf you select the Variable RCD option, it uses an earth leakage relay with adjustable trip level and time delay, giving you a practical way to suit different loads and site conditions instead of being locked into a single setting.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAdjustable trip sensitivity from 30mA up to 10A\u003c\/li\u003e\n\u003cli\u003eSelectable time delay from instantaneous up to 10 seconds (in steps)\u003c\/li\u003e\n\u003cli\u003eKey controlled bypass so only the keyholder can bypass RCD protection when required by a competent person\u003c\/li\u003e\n\u003cli\u003eClear indication when bypass is active, so it is obvious what state the protection is in\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"2947\" data-end=\"2992\"\u003eOutput configuration \u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong data-start=\"2995\" data-end=\"3027\"\u003e12 × 16A single phase outputs\u003c\/strong\u003e, protected by\u003cspan\u003e \u003c\/span\u003etwo pole Type A RCBO \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong data-start=\"3109\" data-end=\"3141\"\u003e6 × 32A single phase outputs\u003c\/strong\u003e, protected by\u003cspan\u003e \u003c\/span\u003etwo pole Type A RCBO \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong data-start=\"3223\" data-end=\"3253\"\u003e2 × 32A three phase output\u003c\/strong\u003e, protection selectable (including Variable RCD option) \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong data-start=\"3223\" data-end=\"3253\"\u003e1 × 63A three phase output\u003c\/strong\u003e, protection selectable (including Variable RCD option) \u003cmeta charset=\"utf-8\"\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"3485\" data-start=\"3469\"\u003eKey specs\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncoming\u003c\/strong\u003e:\u003cstrong\u003e \u003c\/strong\u003e125A three phase, with four pole protection + isolation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndicators\u003c\/strong\u003e: green LED on each output, plus phase rotation indication\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure\u003c\/strong\u003e: impact resistant polypropylene\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP rating\u003c\/strong\u003e: IP44\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEarth lug\u003c\/strong\u003e for secondary bonding\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003esize\u003c\/strong\u003e: 640 x 570 x 450 mm (H X W X D)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eweight\u003c\/strong\u003e: 35kg\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Distro Works","offers":[{"title":"MCB and 30ma RCD","offer_id":52103564984662,"sku":"1253T\/0-12-6\/0-2R-1R","price":2366.0,"currency_code":"GBP","in_stock":true},{"title":"MCB \u0026 Variable RCD","offer_id":52103565017430,"sku":"1253T\/0-12-6\/0-2V-1V","price":2757.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/1740\/3478\/files\/IMG_4332_3.jpg?v=1772667746","url":"https:\/\/distroworks.co.uk\/products\/125a-3-phase-distribution-board","provider":"Distro Works","version":"1.0","type":"link"}